NOTE: I’m pretty sure that most water softeners work very similarly, so even if you don’t have a Kenmore, the information here should be helpful. Choose the RIGHT model with this quick GE water softener model comparison table. Water being used when the water softener is regenerating. Take a clean sturdy wood pole and break it up. The factory default is OFF; however, in the State of California the Salt Saver feature must be used. Sorry Bill. If you found this information helpful, please considering, Click to email this to a friend (Opens in new window), Click to share on Facebook (Opens in new window), Click to share on Twitter (Opens in new window), Click to share on Pinterest (Opens in new window), https://web.archive.org/web/20170930055535/http://kenmorewater.com/Kenmore-main.swf, Winter Park and North Catamount Reservoir – Aug-Sep 2018. When I first set out to repair my water softener, I was expecting to find a complex set of pumps and valves and such. Lay a piece of 2 inch thick board. If you have questions, please post comments, but I’m not plumber and don’t know much more than what I’ve written above ;-) If you found this information helpful, please considering donating to help me keep this blog alive. The animation will walk you though a bunch of steps; however, it’s likely that the problem is in the venturi assembly so, click No when it asks if you cleaned it. Tip the bottom of the softener up a few inches and I don’t want to break it. Mine was engaged. JUST SAVE YOUR FLOW PLUGS FOR VENTURI SYSTEM if replacing. Mine was engaged. It only costs a few dollars more and you’d have all new parts. duh. Hold the base so you don’t crack anything, while twisting counterclockwise. However, because water softeners are installed right at the beginning of the plumbing, they can affect the whole system. When you reassemble the venturi housing, make sure you do it in the correct order and get the small black plugs in their correct spots. In the Brine stage, water is sucked from the brine tank through the same tube used to fill the tank. These particular systems use a brine solution to wash away the hardness minerals and regenerate the sodium-charged resin beads – which are essential to the water softening process. I tried to use a cut off garden hose, but got sick of all the salt water in my mouth so I bought this siphon. GE salt saver, helps reduce salt consumption and uses up to 34% less salt (based on internal analysis verses GE water softeners manufactured prior to 2009) GE exclusive custom select blending valve allows you to select how soft you want your water. I have also found the rubber seal in the bottom of the suction/fill tube does gets stuck in the closed position (when it is filling) and then won’t drop down allowing any of the brine to be siphoned out. You want to make sure no foreign particles are in there messing things up, particularly on the venturi (blue part above). I would also highly recommend a headlamp. You can also save on salt, water, and energy by using up to 50% less detergent for laundry and dishwashing*, using up to 34% less salt and up to 35% less water during regeneration. Examine the large gasket closely. It’s sort of easy to understand how the device can fill and flush out the various tanks with water. This softener has been proven to deliver soft water for at Remove the brine well cover and disconnect the brine It measures 14.4” in width by 22.4” in depth by 47.6” in height and weighs 105 pounds to make maneuvering it non-problematic during the installation process. I have same issue after replacing gasket. There is writing imprinted on the plugs to help you identify them. It’s correct in my blog post. I found 3 small pieces of black hardened debris blocking the inlet of the drain elbow fitting at the softner head and drain hose elbow junction. As a result, canals in the venturi will start to close impeding the flow of water. Unlike our previous choice, this one doesn’t come in pellets. Having the exact same issue. I’m not going to go thorough all the steps since the animation covers it quite nicely, but I’ll elaborate on some important things that are missing or glossed over. //-->. Thanks! Do not allow the softener’s weight to rest on the now?Due to complications he had to empty my water softener and right not it is just as it came from the dealer. The factory default is ON; however it can also be turned off. Refilling the salt in your salt-based water softener is a major part of its ongoing maintenance. 3. We'll step you through the process of putting your water softener in bypass for different types of units. A simple modern pump would be more reliable and efficient. 8. The venturi housing top just unscrews. If that part is working, nearly everything is easily self-serviceable without using any special tools. No, I don’t know how to access that animation now that the site is gone. When I have the float out and put the tube in water, it does not draw anything out. Dang it! As stated above, The flow plug with the smaller hole goes in the venturi (blue part below) and the other one goes in the bottom of the housing. GE have started producing water softeners but are they any good? google_ad_slot = "6432986512"; SLOWLY and hold until all water has drained. Tip unit over following the below procedure and the spray tank out with hot water from garden hose connected to shower head. This is a 25 year old unit. Fix a long water softener regeneration cycle or a water softener that is stuck in regeneration mode: water softener runs too long. Here a few years ago, I have replaced all of the gaskets and plugs, taken apart the entire valve assembly replacing any O-rings and just making sure it was completely clean. Lift The softener has a rated salt efficiency of not less than 4,000 grains of total hardness exchange per pound of salt (based on sodium chloride), and shall not deliver more salt than its listed rating or be operated at a sustained maximum service flow rate greater than its listed rating. The factory default is OFF; however, in the State of California the Salt Saver feature must be used. Self-cleaning sediment filter protects your home's plumbing. What do i do to get it going again? . There is also a tiny screen screen filter which often gets stuck to the large gasket, so be careful not to lose it. To be clear, my tank is holding water as well so I was hoping that the gasket would fix both issues. Do you know how I can find that animation again? Unfortunately, the flash animation does not allow me to progress after using the “no” answer for this issue, lol. GE exclusive custom select blending valve - Allows you to select how soft you want your water GE exclusive salt saver - Helps reduce salt consumption Advanced filtration - Reduces chlorine taste and odor with built-in water filtration Grain capacity - 31,100 › See more product details. s.hier1 = s.prop5; We did NOT siphon the water out of the flooded tank. It sits on top of the venturi which has really tiny canals in it and over time the gasket will conform to them creating the grooves. Instead, you get water softener salt crystals that can both free your water of harmful minerals and ensure the longevity of your water softening system. // Image call I know some people might be impressed with the ‘venturi’ system, but it is old school and -extremely- wasteful of water. Moreover, in 2019 (and for the past 20 years, at least) the brine tank should have a sensor & alamr to prevent overfilling and flooding of the floor or basement… designers are lazy. plastic installation adaptors, or from the bypass You can remove unit and and take take outside. This past time the unit actually overflowed a little bit during the cycle. The 1” full port design allows for the high- 14” X 14” X 36” Space Saver brine tank (for 32,000 gr. Then wat will you do? Thanks for a very helpful article. IT WILL POTENTIALL SHIFT AND STRESS THE THE TOP OF THE UNIT. After I put the Venturi assembly together I found that there was too little water going into the brine tank during the “fill” cycle. I’ve cleaned out the brine tank completely, it was packed solid in the bottom. I use a claw hammer when needed. I was surprised to find none of that. I am not sure if that is normal or not. I have found that if I place 2 sets of O-rings on each of the venture inlets, I get a better seal for suction. My question is not found in these FAQs. I hope this little post helps someone! Could a bad 7204362 gasket cause water pressure issues as well? (This was another helpful site). If it isn’t a bad gasket or dirt in the venturi, make sure the tube to the brine tank is clean and doesn’t have kinks or is broken. Saves up to 50% in salt and uses less water by regenerating only when necessary. Thank you for taking the time to share this info. Specially formulated to outperform other water softening salts, System Saver®II is complete with a patented formula that helps keep your softener clean, problem-free and running longer. To prevent it caking like that, give it a good stir every few days. I turned the bypass off and now my water softener is working. Click where it says “on Amazon for $19”, SeriouslyTrivial.com is a participant in the Amazon Services LLC Associates Program, an affiliate advertising program designed to provide a means for sites to earn advertising fees by advertising and linking to Amazon.com, “I can’t talk to you right now. Basically, you first bypass the softener by pushing in the Bypass Valve plunger, take the hood off the water softener and then disassemble the venturi housing. The only mechanized part is a clock-like component whose purpose is to change the flow of water for the various connections. I had a lot of water in the tank so I siphoned most of it out. To me, this is the most complex portion of the water’s journey through the system and probably why most problems occur here. Most hard water contains traces of dirt, iron and other minerals that can build up in your water softener over time. When used in water softener pellets it is highly effective. A paperclip and small screwdriver are helpful to get the some parts out without dropping and potentially losing them. any luck in the water level going down? This way you can use both hands and still have good light to see inside the mechanism. Backwash and Fast Rinse: If you experience salty tasting water after regeneration, you may need to increase the rinse times up to 10 minutes in 1 minute increments. If you notice that the salt in your brine tank is running low, you’ll need to refill it as soon as possible. A paperclip can be used to clean the holes on the small black flow plugs. the salt hole cover and the main cover. New (3) from $799.00 + FREE Shipping. Softenerparts.com. No tools needed. Today we are going to tell you how you can put your water softener in bypass. I had no water readings for days. As expected, GE water softener units are designed to combat hard water problems within a specific area. Wish I could be more help. Is the timing mechanism designed to stop the water as well? Water softeners are designed to prevent minerals from scaling on your pipes and fixtures, but funnily enough, they are subject to salt – which is still a mineral – scaling inside the tank and within the system’s lines. My water tank is filled with water it’s usually filled with salt I’m not sure what’s going on. Once I got these kirks figured out, it works perfectly. Thank you. Excessive water usage. my brine tank was always full and little softening taking place. Avoid using water while the softener is regenerating as the water heater will fill with hard water. A leaking faucet or toilet valve. Warm soapy water can be used on all of the parts. NOTE: THE KENMORE GE AND MAYTAG SOFTENERS USE THE EXACT SYSTEMS (VENTURI, FLOAT, TIMER SWITCH….. . valve upside down to drain water. google_ad_width = 180; out. More. ** These water softeners also feature I would think right above the salt. Adding bleach to with warm water may help to dissolve solid mass of Salt before removal of unit. CAREFULLY, tip it over until the rim rests on the Bill, try this link https://web.archive.org/web/20170930055535/http://kenmorewater.com/Kenmore-main.swf but note that it does not work in Chrome. ONCE SOLID SALT IS REMOVED. two tank model) Water Treatment Professional Two Tank Models – Commercial. Evaporated Salt Pellets- Evaporated salt is of 100% purity, the purest form of all sodium-based water softener pellets. the brine valve out of the brine well. REMEMBER THAT THE RESIN TANK WILL SHIFT Where do I look next? (If you want to know more, the How Your Water Softener Works section in the user guide was extremely helpful.). I can cycle the system and the water in the tank drains out but seems to be filling again. Thanks. Originally posted on www.ge.com. Brine and backwashing water should now be done by a pump, not a venturi. Remove the cap from the brine well and again dump in some hot water. wood block with the inlet and outlet over the drain. If I had to do it over, I would have just ordered the whole Venturi and nozzle assembly (7238450). So right where it comes out of the softener head. BLOCK WITH A CLEAN BLANKET OR SOMETHING WHEN MOVING UNIT BACK IN. I’m not doing stupid at the moment.”,